Model 2000SPA-X RH Generator conforming to specifications. The Certificate of Conformance is to ISO/IEC 17025 procedures. Report of Calibration for the secondary transfer standards provided by NVLAP Accredited Laboratory with NIST traceability.

System includes:

  • 1 each – Desiccant Tube, Molecular Sieve/Indicating Desiccant
  • 1 each – Chamber Door, 5 Port, (select port sizes 12mm, 15mm, 18mm, in any combination)
  • 2 each – Water Syringe
  • 1 set – KayCal Software for automatic Ramp/Soak Operation
  • 1 set – Certificates of Calibration

Description

Finally…. A Humidity Generator that Stabilizes in less than 5 minutes, has the Capacity to Calibrate 12 Probes and can Complete a 3 Point RH Calibration of Chart Recorders with Embedded Sensors in 60 minutes…Automatically!!!

The M2000SPA-X combines high performance and high accuracy with an affordable cost which results in a system suitable for laboratory or field calibrations of RH and temperature instruments. There are several options and accessories to be offered which expand the area of calibration capabilities.The addition of external chambers, which are attached to the primary system, will provide a means for data logger and chart recorder calibrations.The M2000SPA is the only system which is supplied with certificates of conformance and reports of calibration from an NVLAP Accredited laboratory for a high precision transfer standard. The M2000SPA is the only system supplied with a certificate of conformance which presents the actually difference between a controller set point value and the actual conditions within the internal chamber. The M2000SPA is the only system which can be supplied (optional calibration request) with comparison data for chamber readings against an NVLAP calibrated transfer standard at 10°C and 40°C. 

 

Contact us to discuss your application / options and pricing.

 

Specifications

Features & Benefits

  • Range of operation 5-95%RH @ 23°C and temperature of <15°C below ambient to 55°C
  • Accuracy of ±0.8%RH over range of 5-95%RH @ 23°C, with an overall accuracy of <±1.25%RH over the operating temperature range of 10°-40°C
  • Performance verified using an NVLAP calibrated transfer standard which has been adjusted to readings of instrumentation with a k=2 uncertainty of ±0.3%RH and ±0.036°C
  • Temperature compensated control probes for high accuracy over full range of operation
  • Controller set point values after stabilization compared to actual chamber readings at 10%, 35%, 50%, 80% and 95%RH and verified to be within a tolerance of 0.5%RH or better
  • Response time of <5minutes for a 70%RH step change with full RH and temperature stabilization
  • Closed loop operation for longer operation of desiccant resulting in more cost efficiency
  • Chamber doors available for multiple probe calibrations with 12, 15, 18 and 25mm diameters
  • External chamber (optional) with clear doors for calibrating instruments with digital displays
  • External chamber (optional) with multiple ports for calibration of 12 probes
  • External chamber (optional) with clear door for calibration of 8” chart recorders with embedded sensors. All external chambers best suited for accurate performance at ambient temperature
  • Completely self contained. No external air supply or water required
  • Extremely rugged carrying case (optional) for fully protected transportation
  • No special preparation required before transporting. No water to empty
  • Low cost desiccant replacement kit saves time when desiccant agents are no longer useable
  • Software for automatic, unattended ramp/soak operations for determining data logger or chart recorder accuracy and linearity over the required operating range
  • Annual calibration of the system or the in-house reference instrument is recommended